See What's New at GlobeBit!
NEW! We're Hiring! See our
employment
section for details!
CATS-1000
Specifications NEW!
CATS-2000
Specifications NEW!
CATS-1000 & 2000 Brochure
"CATS" = Test, Measure, & Control Solutions
FSC-1000
GlobeBit Soft-Controller for DO-178B Software Verification and Validation
LTS-1000 Lighting Tester and High Speed Data Logging System
RFA-1000
Programmable RF Attenuator
|
CATS-2000
"Configurable Automated Test System"
Standard Delivery= 50 Days ARO
Price........... $148,500
- 1 Year Warranty on Hardware
- 90 Day Warranty on Software
- On Site Installation & Training
|
Dimensions: 42.31"H x 23.0"W x 36"D
|
CATS-2000 HW Description:
(1) 22-pin BNC-2090A shielded rack-mount 1/0 connector panel
(1) BNC input in support of 250 MHz/s digitizer/oscilloscope
(48) BNC inputs supporting Industrial 24V Input, optically isolated
(32) BNC inputs in support of 18 bit SOOkS/s Analog inputs
(16) BNC inputs in support of 250kS/s 16 bit Analog input
(6) Three-port channels in support of two three phase measurements,
each consisting of self-fused (SA) system with Vin, Vout and Vref
|
Module (Analog Input(1) Description (included) |
Module (Analog Input(2)) Description (included) |
[2 X] Channels |
16 |
Channels |
16 |
Single-Ended Channels |
16 |
Single-Ended Channels |
16 |
Differential Channels |
8 |
Differential-Ended Channels |
8 |
Resolution |
18 bits |
Resolution |
16 bits |
Sample Rate |
625 kS/s |
Sample Rate |
250 kS/s |
Max Voltage |
lO V |
Voltage Range |
±lOV |
Maximum Voltage Range |
±10V |
Sensitivity |
97.6 uV |
Maximum Voltage Range Accuracy |
980 uV |
Accuracy |
112 uV |
Minimum Voltage Range |
± 100 mV |
Ranges |
4 |
Minimum Voltage Range Accuracy |
28 uV |
|
|
Module (Digitizer/Oscilloscope) Description (included) |
Module (Industrial Digital Input) Description (included) |
Channels |
2 |
Channels |
48 |
Resolution |
8 bits |
Timing |
Software |
Simultaneous samples |
Yes |
Logic Levels |
24V |
Sample Rate |
250 MS/s |
Input Current Flow |
Sink/Source |
Bandwidth |
125 MHz |
Max input range |
±60V |
Input Impedance |
50 /lMOhm |
Programmable Filters |
Yes |
Max Common Mode Voltage |
35 V |
Watchdog Timer |
No |
Max Voltage |
±20V |
Handshaking |
No |
Frequency Range |
0-125 MHz |
Pattern 1/0 |
No |
Minimum Voltage Range |
20 mV |
|
|
Module (Current Input) Description (included) |
Module (Voltage Input) Description (included) |
Channels |
4 |
[2X] Channels |
3 |
Single-Ended Channels |
0 |
Single-Ended Channels |
0 |
Differential Channels |
4 |
Differential Channels |
3 |
Resolution |
24 bits |
Resolution |
24 bits |
Sample Rate |
50 kS/s |
Sample Rate |
50 kS/s |
Max Voltage |
24.6 kHz |
Bandwidth |
24.56 kHz |
Maximum Current Range |
± 5A |
Max Voltage |
300V |
Maximum Current Range Accuracy |
0.11 mA |
aximum Voltage Range |
± 300V |
Simultaneous Sampling |
Yes |
Maximum Voltage Range Accuracy |
300 µV |
Input Impedance |
12 mOhm |
Simultaneous Sampling |
Yes |
|
|
Input Impedance |
1 MOhm |
CATS-2000 Software (SW) Description
The CATS-2000 family of equipment is typically associated with the higher powered NI-PXI chassis with built-in processor controller, specialized operating systems build specifically for NI embedded control, and the capability for fast and plentiful data I/O.
This CATS-2000 specification is targeted toward a unit developed specifically for power distribution system analysis and certification. The unit is built within an EMI shielded 19” rack enclosure with a shielded input system as it was designed to be placed in a highly “noisy” electronic environment, and system operation was intended to be controlled and viewed remotely via a 500’ fiber optic link. The unit hardware was built for 3 phase voltage and current measurement over a variety of test scenarios controlled by the CATS-2000.
Standard Main GUI
This is the basic 5 layer CATS graphical user interface (GUI) accompanying the Fastek CATS operating system. The CATS user’s Guide leads operators to the specifics of setting up an executing test, measurement or control operations specific to their desires with minimal effort.
3 Phase Current Configure/Control
Fastek’s 3 Phase Current module provides an interface to a wide variety of general purpose analog input platform. The modules support platforms with a current range of +/- 5A, sampling rates up to 50Ks per seconds, and 24 bits of sample resolution. Fastek’s highly scalable application architecture supports multiple current input modules each controlling 4 channels, or greater.
3 Phase Voltage Configure/Control
Fastek’s 3 Phase Voltage module accommodates interfaces to many different general purpose analog input platforms. The module here supports platforms with a voltage range of +/- 300V, sampling rates up to 50Ks per second, and 24 bits per sample of resolution. Fastek’s CATS O/S supports multiple analog input modules each controlling 3 channel, or greater, single ended and differential DAQ hardware.
Analog Input Configure/Control
Fastek’s generic Analog input Module may also be used over a wide variety of NI analog input cards. In this application the unit is configured to both; a 625k Samples per second analog input/counter and a 250kS/s analog input device. This configuration supports inputs in the range of +/- 10V with 18/16 bits of resolution. All Fastek modules may be configured to share configurations.
Data Logger Module
This CATS-2000 data logging capacity can be set for short (per run) or specified (targeted) data recording, or continuous data logging. In the continuous mode it may be run for long term, bounded only by the available data storage space and logging speed ability. Storage may be on the local controller or directly to the operator specified database with the operator specific schema. Data recording includes pre/post and partial triggering capability as well as operator specified scaling.
Digital input & Oscilloscope Configure/Control
Fastek’s CATS-2000 digital input implemented in this system is also only a specific instance of many digital I/O supported by the flexible CATS operating system. IN this configuration the software is configured to support up to 48 channels of input for 24 VDC logic levels. As with any of the data, this is available for logging, triggering, or changing the course of the unit operation as specified by the operator.
Sometimes witnessing the repetition, event occurrence, or other pertubations in signals is necessary in test, measurement and control. The Fastek CATS is compatible with all NI (and third party) equipment. This CATS-2000 supports a 250S/s 8-bit digitizer/o-scope for real-time recording of signals during test, measurement or control. With the versatility of the NI equipment and the Fastek CATS LabVIEW based software, this signal can not only be recorded but used as trigger events for other unit operations.
|
Request Information
Fill out the following form with any questions or comments you might have and we will get back to you.
Please enter a valid email
Avionics
Industrial & Manufacturing
Embedded Software
Web/Windows Development
Other
|